Features
? Dual input: pipe to soil and shunt
? Portable and rugged
? GPS synchronization with other survey
equipment
? Programmable waveform capture
? Every reading is time stamped
? ASCII comma delimited text file
? No special software required
? Comprehensive 1 year warranty
Ideal for
? Correction of CIPS data for stray currents
? Correction of CIPS data for tellurics
? Monitor pipe to soil potentials
Technical Specification
? Range - Channel 1: +/- 5 V DC or +/- 25 V DC
? Range - Channel 2: +/- 50 mV
? A/D Converter: 14 bit
? AC Rejection: 100 dB
? Memory Capacity: 1 Mb, expandable to 2Mb
? Input Impedance: 10 M ohm or 250 M ohm
? Case: Plastic with o-ring seal, IP67 rated
? Dimensions: 27cm x 25cm x 13cm (10.5” x 10” x 5”)
? Weight: 3.2 kg (7 lb)
? Battery: 7.2V 4.5 amp hour NiMH
? User interface: 240 x 64 graphic LCD with 40 key QWERTY membrane keypad
? Communications: RS-232
? GPS synchronized with external antenna
? Option to log GPS co-ordinates with every reading
Included
? Smart Logger II
? Test leads
? GPS magnet mount antenna
? AC charger; 120/240 V AC, 50/60 Hz
input
? RS-232 cable
? USB to RS-232 converter
? Owners manual